TEPCO revised unit 2’s containment inspection radiation readings done earlier in 2017, claiming a set of instrument and calibration errors caused the inaccurate readings.
TEPCO claims that their camera based radiation estimates were too high due to an oversight where they forgot to reset the sensitivity threshold on the equipment that was reading camera interference.
The final claim made in the report for downgrading the radiation readings was that one of the 4 sensors was reading considerably higher than the other 3. When they took that sensor out of the readings the other 3 sensors read considerably lower.
Source : Tepco’s handout
http://www.tepco.co.jp/en/nu/fukushima-np/handouts/2017/images/handouts_170727_03-e.pdf